Email address: [email protected]

Commonly used vacuum degree: less than 60kPa (except CBX/type A)

Common exhaust pressure: less than 60kPa (except CBX. Type A)

Flow rate: 280 ~ 1115L/min(60Hz)

Speciality:

Because of the dual-cylinder and dual-function (vacuum pump and blower are side-by-side) mode, it can be used as a vacuum source with a vacuum degree below 60kPa and an air source with exhaust pressure below 60kPa independently.

Compared with the previous compound pump, this pump is small in volume and light in weight (compared with the company's pump), and easy to operate.

Specification

Model Rotate Speed (rpm) Design air displacement(L/min) (※1) Common vacuum degree (below kPa) (※3) Common exhaust pressure (below kPa)(※3) Pipe Connection Aperture Power source The loading motor(KW) Weight(kg)
Three phase
200V 380V
50Hz 50Hz 
CBX□
15-P-VB-03 1730 280 60 60 Rc3/4 0.75 41
25-P-VB-03 1730 480 60 60 Rc3/4 1.5 53
40-P-VB-03 1730 685 60 60 Rc3/4 2.2 69
62-P-VB-03 1370 1115 60 60 Rc1 4.0 110
CBX□
15-P-VBVB-03 vacuum 1730 280 55 20 Rc3/4 0.75 41
forced draft 35 50 Rc3/4
25-P-VBVB-03 vacuum 1730 480 55 20 Rc3/4 1.5 53
forced draft 35 50 Rc3/4
40-P-VBVB-03 vacuum 1730 685 55 20 Rc3/4 2.2 69
forced draft 35 50 Rc3/4

※ 1 Design displacement: theoretical value calculated from volume. The actual flow rate refers to the measured data of performance

※ 3 Possible range of vacuum degrees (exhaust pressure) to be used.

The speed of the vacuum pump is designed to be 60Hz when the speed, cannot be used in 60Hz area, when used in 60Hz, please contact the agent or manufacturer.

Using the environment (inhaled air) conditions: temperature: 0 ~ 40 ℃, humidity: usually humidity (65 + / - 20%)

The allowable fluctuation range of power supply voltage is rated voltage plus or minus 10%.

Please set up overload protector (thermal relay, etc.).

The set value shall be 110% at 50Hz, 120% at 50Hz (with the same performance as 60Hz), 120% at 60Hz.